Biến tần | Inverters

Thông tin chi tiết về SINAMICS G120P, built-in and wall-mounted units, IP20/IP54/IP55 > PM240P-2 Power Modules, 11 kW to 132 kW của SIEMENS

Phần cứng mới. Đạt hiệu điện cao, an toan, nhỏ gọn, 380V...480V 3AC và 500V...690V 3AC. PM240P-2. Ứng dụng hệ thống quản lý tòa nhà; nhà máy công nghiệp: Quạt, máy bơm, máy nén, ...
Thông tin chi tiết về SINAMICS G120P, built-in and wall-mounted units, IP20/IP54/IP55 > PM240P-2 Power Modules, 11 kW to 132 kW của SIEMENS
PM230 Power Modules, degree of protection IP54, frame sizes FSA to FSF (with operator panel)
 

Tóm tắt về sản phẩm SINAMICS G120P Built-In and Wall-Mounting Units 

Options with added value: for your applications in heating, ventilation and air-conditioning systems

 

Whether installed in the intake and exhaust fans of air-conditioning systems, in pumps for heating and cooling circuits, or in compressors for refrigeration units: SINAMICS G120P converters are ideally suited to meet every requirement of building management systems.
 

Flexible installation

Stay flexible: Due to their IP20 and IP55 degrees of protection, the PM230 Power Modules can not only be installed in the control cabinet, but can also be directly at the machine. And thanks to different EMC filters, they can be used both in the public power grid and in industrial networks.
 

Special functionality

A well-thought-out portfolio: Apart from standard functions such as setpoint specifications, on/off switching logic, protection and monitoring of machine, motor and converter, SINAMICS G120P also offers numerous industry-specific functions. These include the regulation of two or multiple zones and one fire protection mode which ensures the longest possible operation in an emergency.
 

Highlights at a glance – specially developed for your applications in building management systems

- Full control – Real-time clock with exact time stamp for error and warning logging, max. buffer time five days, automatic summer / winter changeover

- Freely programmable – Digital timers for the control of three selectable events depending on the weekday / hour / minute

SINAMICS G120P in the Building Technologies:

Power:

0,37 - 90 kW

Voltage:

3 AC 380 - 480 V

Control procedure:

U/f control with stator flux orientation, vector control without encoder

 

SINAMICS G120P – options with added value: for your industrial applications

Growing complexity of plants and globalization of markets: The drives of the SINAMICS G120P series always have the right answer for the special features of the process industry.
 

Simply practice-oriented

Usable and available worldwide – SINAMICS G120P is ready to meet your global requirements. And with the key functions of speed control, controlling range, efficiency and communication level, it ensures simple operation.
 

Maximum flexibility

Thanks to the upgraded PM330 Power Modules, you now have a complete series of SINAMICS G120P products at your disposal: in all sizes and across all voltage ranges, from 400 V to 690 V. A flexibly applicable and consistent approach, which minimizes your configuration and implementation overheads.
 

Reliably safeguarded

The new PM240P-2 Power Modules increases your process reliability: with integrated safety functionality up to the SIL3 level.

Highlights at a glance – specially developed for your industrial applications

The new Power Modules PM240P-2

- Process reliability – Utmost safety level thanks to Integrated safety functions, safe electronic switch-off (Safe Torque-off / Safe Stop 1)

- Robustness – Even for special operating conditions such as temperatures ranging from -10° C to 60° C and aggressive environments (resistance to pollutants)

- Cost saving – Increased energy efficiency with higher output voltage (98 %) through integrated dc link reactor
 

The innovated Power Modules PM330

- Enhanced flexibility – due to the new voltage level up to 690 V

- Saving space – allows compact control cabinets

- Robustness – through numerous functions such as output voltage sensing

- Total integration – the complete product series is available

SINAMICS G120P in the Process industry

Power:

11 - 630 kW

Voltage:

3 AC 380 - 480 V and 3 AC 500 - 690 V

Control procedure:

U/f control with stator flux orientation, vector control without encoder

 

Details on SINAMICS G120P built-in and wall-mounted devices

Power Modules

SINAMICS G120 Power Modules

Power Modules for industrial applications and building technology

 

Control Units

SINAMICS G120 Control Units

Control Units have been especially designed for pump, fan, compressor applications

 

Accessories

SINAMICS G120 Optionen

Supplementary system components for SINAMICS G120P


SINAMICS G120P Inverters > PM240P-2 Power Modules, 11 kW to 132 kW

Offer a Comprehensive Range of Power Modules for pumps, fans and compressors Applications

 

Overview

 

The new PM240P‑2 Power Modules are based on a new hardware platform. This permits a higher power density to be achieved. PM240P-2 Power Modules do not have an integrated braking chopper.
 

In addition, PM240P-2 Power Modules are also suitable for use in safety-related applications. In conjunction with an external tripping unit (e.g. SIRIUS 3SK1), the drive becomes a Safety Integrated Drive with the Safe Torque Off (STO) safety function with a maximum Safety Integrity Level of SIL 3.
 

PM240P-2 Power Modules, frame sizes FSD to FSF, are available both with and without an integrated line filter class A in a compact design for line voltages of 380 V to 480 V 3 AC and 500 V to 690 V 3 AC. PM240P‑2 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without an integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.
 

The permissible cable lengths between inverter and motor are limited (for max. permissible cable lengths, see section Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).
 

Note:

Shield plates and shield connection kits are available. These can be used in the wiring installation for the Control Units and Power Modules to ensure that it complies with EMC guidelines.

For more information, see Shield connection kits and shield plates for Control Units and Power Modules in section Supplementary system components.

 

Integration

All PM240P-2 Power Modules have the following connections and interfaces:

  • PM‑IF interface to connect the Power Module to the Control Unit. The Power Module also supplies power to the Control Unit using an integrated power supply
  • Motor connection using screw-type terminals or screw studs
  • 2 PE/protective conductor connections
  • Connection for STO via terminals on Power Module with DIP switch


Connection diagram for PM240P-2 Power Module with or without integrated line filter class A

Available optional power components

The following load-side power components are optionally available in the appropriate frames sizes for the Power Modules:

PM240P-2 Power Module

System operating voltage

Frame size

FSD

FSE

FSF

Output reactor

380 ... 480 V 3 AC

500 ... 690 V 3 AC

✓ 

✓ 

✓ 

✓ 

dv/dt filter plus VPL

500 ... 690 V 3 AC

✓ 

✓ 

✓ 

Maximum permissible cable lengths from the motor to the inverter when using output reactors or dv/dt filters depending on the voltage range

The following load-side power components in the appropriate frame sizes are optionally available for the Power Modules and result in the following maximum cable lengths:

PM240P-2 Power Module, frame sizes FSD and FSE

System operating voltage

Maximum permissible motor cable lengths (shielded/unshielded) in m (ft)

Without output option

380 ... 480 V 3 AC

200/300 (656/984)

Without output option, compliance with Category C2 acc. to EN 61800-3

380 ... 480 V 3 AC

150/- (492/-)

With two output reactors in series

380 ... 480 V 3 AC

350/525 (1148/1722)

With dv/dt filter plus VPL

500 ... 690 V 3 AC

300/450 (984/1476)

 

PM240P-2 Power Module, frame size FSF

System operating voltage

Maximum permissible motor cable lengths (shielded/unshielded) in m (ft)

Without output option

380 ... 480 V 3 AC

500 ... 690 V 3 AC

300/450 (984/1476)

300/450 (984/1476)

Without output option, compliance with Categories C2 and/or C3 acc. to EN 61800-3

380 ... 480 V 3 AC

500 ... 690 V 3 AC

150/- (Category C2)

150/- (Category C3)

With two output reactors in series

380 ... 480 V 3 AC

500 ... 690 V 3 AC

525/800 (1722/2625)

525/800 (1722/2625)

With dv/dt filter plus VPL

500 ... 690 V 3 AC

300/450 (984/1476)

 

Technical specifications

General technical specifications

Power Modules

PM240P-2

System operating voltage

380 ... 480 V 3 AC ±10 % (in operation -20 % < 1 min)

500 ... 690 V 3 AC ±10 % (in operation -20 % < 1 min)

Grid requirement
Short-circuit power RSC

>25

Input frequency

47 ... 63 Hz

Output frequency

 

  • Control mode U/f

0 ... 550 Hz

  • Control type Vector

0 ... 200 Hz

Pulse frequency

 
  • At 380 ... 480 V 3 AC ±10 %

up to 90 kW (121 hp) (LO): 4 kHz

from 110 kW (148 hp) (LO): 2 kHz

Higher pulse frequencies up to 16 kHz, see derating data

  • At 500 ... 690 V 3 AC ±10 %

2 kHz, can be adjusted to 4 kHz

Power factor λ

0.95 at 380 ... 480 V 3 AC

0.9 at 500 ... 690 V 3 AC

Offset factor cos φ

0.99

Inverter efficiency

>97 % at 380 ... 480 V 3 AC

>98 % at 500 ... 690 V 3 AC

Output voltage, max.

In % of input voltage

95 %

Overload capability

 

  • Low overload (LO)

Note:

When the overload capability is used, the base-load current IL is not reduced.

1.35 × base-load current IL (i.e. 135 % overload) for 3 s plus 1.1 × base-load current IL (i.e. 110 % overload) for 57 s within a cycle time of 300 s

  • High overload (HO)

Note:

When the overload capability is used, the base-load current IH is not reduced.

1.5 × base-load current IH (i. e. 150 % overload) for 60 s within a cycle time of 300 s

Electromagnetic compatibility

  • Devices without line filter
  • Devices with line filter class A for compliance with conducted and radiated interference requirements of Category C2

Possible braking methods

  • DC braking
  • Compound braking

Degree of protection

IP20

Operating temperature

 

  • Low overload (LO)

-20 ... +40 °C (-4 ... +104 °F) without derating
>40 ... 60 °C (>104 ... 140 °F) see derating characteristics

  • High overload (HO)

-20 ... +50 °C (-4 ... +122 °F) without derating
>50 ... 60 °C (>122 ... 140 °F) see derating characteristics

Relative humidity

5 … 95 %, condensation not permitted

Storage temperature

-25 ... +55 °C (-13 ... +131 °F)

Cooling

Internal air cooling, power units with increased air cooling by built-in fans

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 m (3281 ft) see derating characteristics

Protection functions

  • Undervoltage
  • Overvoltage
  • Overcurrent/overload
  • Overtemperature
  • Ground fault
  • Short-circuit
  • Stall protection
  • Motor blocking protection
  • Motor overtemperature
  • Inverter overtemperature
  • Parameter locking

Short-Circuit Current Rating SCCR

(Short-Circuit Current Rating) 1)

65 kA

Compliance with standards

UL, cUL, CE, RCM, SEMI F47

CE marking

According to Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU

 

1) Applies to industrial control panel installations to NEC article 409 or UL 61800-5-1.

PM240P-2 Power Modules

Line voltage 380 ... 480 V 3 AC

PM240P-2 Power Modules

Without integrated line filter

6SL3210-1RE24-5UL0

6SL3210-1RE26-0UL0

6SL3210-1RE27-5UL0

6SL3210-1RE28-8UL0

6SL3210-1RE31-1UL0

With integrated line filter

6SL3210-1RE24-5AL0

6SL3210-1RE26-0AL0

6SL3210-1RE27-5AL0

6SL3210-1RE28-8AL0

6SL3210-1RE31-1AL0

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

  • Rated current Irated1)

A

45

60

75

90

110

  • Base-load current IL1)

A

45

60

75

90

110

  • Base-load current IH2)

A

38

45

60

75

90

  • Maximum current Imax

A

61

81

102

122

149

Rated power

 

 

 

 

 

 

  • Based on IL

kW

22

30

37

45

55

  • Based on IH

kW

18.5

22

30

37

45

Rated pulse frequency

kHz

4

4

4

4

4

Efficiency η

%

98

98

98

98

98

Power loss 3)

at rated current

 

 

 

 

 

 

  • Without integrated line filter

kW

0.7

0.85

1.12

1.25

1.59

  • With integrated line filter

kW

0.71

0.85

1.12

1.28

1.63

Cooling air requirement

m3/s (ft3/s)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.083 (2.93)

0.083 (2.93)

Sound pressure level

LpA (1 m)

dB

71.6

71.6

71.6

70.6

70.6

24 V DC power supply

for Control Unit

A

1

1

1

1

1

Rated input current Irated4)

 

42

57

70

86

104

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw terminal

Screw terminal

Screw terminal

Screw terminal

Screw terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

25 ... 70

25 ... 70

Motor connection

U2, V2, W2

 

Screw terminal

Screw terminal

Screw terminal

Screw terminal

Screw terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

25 ... 70

25 ... 70

Feedback connection

F3, R1

 

Screw terminal

Screw terminal

Screw terminal

Screw terminal

Screw terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

25 ... 70

25 ... 70

PE connection

 

Screw terminal

Screw terminal

Screw terminal

Screw terminal

Screw terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

25 ... 70

25 ... 70

Motor cable length 5), max.

 

 

 

 

 

 

  • Shielded

m (ft)

200 (656)

200 (656)

200 (656)

200 (656)

200 (656)

  • Unshielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

300 (984)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

200 (7.87)

200 (7.87)

200 (7.87)

275 (10.8)

275 (10.8)

  • Height

mm (in)

472 (18.6)

472 (18.6)

472 (18.6)

551 (21.7)

551 (21.7)

  • Depth

 

 

 

 

 

 

  • Without operator panel

mm (in)

237 (9.33)

237 (9.33)

237 (9.33)

237 (9.33)

237 (9.33)

  • With Control Unit and operator panel, max.

mm (in)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

Frame size

 

FSD

FSD

FSD

FSE

FSE

Weight, approx.

 

 

 

 

 

 

  • Without integrated line filter

kg (lb)

16.6 (36.6)

18.3 (40.3)

18.3 (40.3)

26 (57.3)

26 (57.3)

  • With integrated line filter

kg (lb)

18.3 (40.3)

19 (41.9)

19 (41.9)

28 (61.7)

28 (61.7)

 

1) The rated output current Irated and the base-load current IL are based on the duty cycle for low overload (LO).

2) The base-load current IH is based on the duty cycle for high overload (HO).

3) Maximum values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uK = 1 %.

5) The specified cable lengths apply to Power Modules without output option and without compliance with the limit values for RI suppression.

Line voltage 380 ... 480 V 3 AC

PM240P-2 Power Modules

Without integrated line filter

6SL3210-1RE31-5UL0

6SL3210-1RE31-8UL0

6SL3210-1RE32-1UL0

6SL3210-1RE32-5UL0

With integrated line filter

6SL3210-1RE31-5AL0

6SL3210-1RE31-8AL0

6SL3210-1RE32-1AL0

6SL3210-1RE32-5AL0

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

  • Rated current Irated1)

A

145

178

205

250

  • Base-load current IL1)

A

145

178

205

250

  • Base-load current IH2)

A

110

145

178

205

  • Maximum current Imax

A

196

214

277

338

Rated power

 

 

 

 

 

  • Based on IL

kW

75

90

110

132

  • Based on IH

kW

55

75

90

110

Rated pulse frequency

kHz

4

4

2

2

Efficiency η

%

98

98

98

98

Power loss 3)

at rated current

 

 

 

 

 

  • Without integrated line filter

kW

1.58

2.07

2.28

2.97

  • With integrated line filter

kW

1.6

2.1

2.31

3.01

Cooling air requirement

m3/s (ft3/s)

0.153 (5.40)

0.153 (5.40)

0.153 (5.40)

0.153 (5.40)

Sound pressure level

LpA (1 m)

dB

67.7

67.7

67.7

67.7

24 V DC power supply

for Control Unit

A

1

1

1

1

Rated input current Irated4)

A

140

172

198

242

Line supply connection

U1/L1, V1/L2, W1/L3

 

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Motor connection

U2, V2, W2

 

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Feedback connection

F3, R1

 

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

35 ... 2 x 120

35 ... 2 x 120

35 ... 2 x 120

35 ... 2 x 120

PE connection

 

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Motor cable length 5), max.

 

 

 

 

 

  • Shielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

  • Width

mm (in)

305 (12.01)

305 (12.01)

305 (12.01)

305 (12.01)

  • Height

mm (in)

708 (27.9)

708 (27.9)

708 (27.9)

708 (27.9)

  • Depth

 

 

 

 

 

  • Without operator panel

mm (in)

357 (14.06)

357 (14.06)

357 (14.06)

357 (14.06)

  • With Control Unit and operator panel, max.

mm (in)

394.5 (15.5)

394.5 (15.5)

394.5 (15.5)

394.5 (15.5)

Frame size

 

FSF

FSF

FSF

FSF

Weight, approx.

 

 

 

 

 

  • Without integrated line filter

kg (lb)

57 (126)

57 (126)

61 (134)

61 (134)

  • With integrated line filter

kg (lb)

63 (139)

63 (139)

63 (139)

63 (139)

 

1) The rated output current Irated and the base-load current IL are based on the duty cycle for low overload (LO).

2) The base-load current IH is based on the duty cycle for high overload (HO).

3) Maximum values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uK = 1 %.

5) The specified cable lengths apply to Power Modules without output option and without compliance with the limit values for RI suppression.

Line voltage 500 ... 690 V 3 AC

PM240P-2 Power Modules

Without integrated line filter

6SL3210-1RH21-4UL0

6SL3210-1RH22-0UL0

6SL3210-1RH22-3UL0

6SL3210-1RH22-7UL0

6SL3210-1RH23-5UL0

6SL3210-1RH24-2UL0

With integrated line filter

6SL3210-1RH21-4AL0

6SL3210-1RH22-0AL0

6SL3210-1RH22-3AL0

6SL3210-1RH22-7AL0

6SL3210-1RH23-5AL0

6SL3210-1RH24-2AL0

Output current

at 50 Hz 690 V 3 AC

 

 

 

 

 

 

 

  • Rated current Irated1)

A

14

19

23

27

35

42

  • Base-load current IL1)

A

14

19

23

27

35

42

  • Base-load current IH2)

A

11

14

19

23

27

35

  • Maximum current Imax

A

19

26

32

37

48

57

Rated power

 

 

 

 

 

 

 

  • Based on IL

kW

11

15

18.5

22

30

37

  • Based on IH

kW

7.5

11

15

18.5

22

30

Rated pulse frequency

kHz

2

2

2

2

2

2

Efficiency η

%

98

98

98

98

98

98

Power loss 3)

at rated current

 

 

 

 

 

 

 

  • Without integrated line filter

kW

0.36

0.45

0.52

0.61

0.77

0.94

  • With integrated line filter

kW

0.36

0.45

0.53

0.61

0.78

0.94

Cooling air requirement

m3/s (ft3/s)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

Sound pressure level

LpA (1 m)

dB

71.6

71.6

71.6

71.6

71.6

71.6

24 V DC power supply

for Control Unit

A

1

1

1

1

1

1

Rated input current Irated4)

A

14

18

22

25

33

40

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

Motor connection

U2, V2, W2

 

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

Feedback connection

F3, R1

 

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

PE connection

 

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

Screw-type terminal

  • Conductor cross-section

mm2

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

10 ... 35

Motor cable length 5), max.

 

 

 

 

 

 

 

  • Shielded

m (ft)

200 (656)

200 (656)

200 (656)

200 (656)

200 (656)

200 (656)

  • Unshielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

300 (984)

300 (984)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

200 (7.87)

200 (7.87)

200 (7.87)

200 (7.87)

200 (7.87)

200 (7.87)

  • Height

mm (in)

472 (18.6)

472 (18.6)

472 (18.6)

472 (18.6)

472 (18.6)

472 (18.6)

  • Depth

 

 

 

 

 

 

 

  • Without operator panel

mm (in)

237 (9.33)

237 (9.33)

237 (9.33)

237 (9.33)

237 (9.33)

237 (9.33)

  • With Control Unit and operator panel, max.

mm (in)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

274.5 (10.8)

Frame size

 

FSD

FSD

FSD

FSD

FSD

FSD

Weight, approx.

 

 

 

 

 

 

 

  • Without integrated line filter

kg (lb)

17.4 (38.4)

17.4 (38.4)

17.4 (38.4)

17.4 (38.4)

17.4 (38.4)

17.4 (38.4)

  • With integrated line filter

kg (lb)

18.9 (41.7)

18.9 (41.7)

18.9 (41.7)

18.9 (41.7)

18.9 (41.7)

18.9 (41.7)

 

1) The rated output current Irated and the base-load current IL are based on the duty cycle for low overload (LO).

2) The base-load current IH is based on the duty cycle for high overload (HO).

3) Maximum values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uK = 1 %.

5) The specified cable lengths apply to Power Modules without output option and without compliance with the limit values for RI suppression.

Line voltage 500 ... 690 V 3 AC

PM240P-2 Power Modules

Without integrated line filter

6SL3210-1RH25-2UL0

6SL3210-1RH26-2UL0

6SL3210-1RH28-0UL0

6SL3210-1RH31-0UL0

6SL3210-1RH31-2UL0

6SL3210-1RH31-4UL0

With integrated line filter

6SL3210-1RH25-2AL0

6SL3210-1RH26-2AL0

6SL3210-1RH28-0AL0

6SL3210-1RH31-0AL0

6SL3210-1RH31-2AL0

6SL3210-1RH31-4AL0

Output current

at 50 Hz 690 V 3 AC

 

 

 

 

 

 

 

  • Rated current Irated1)

A

52

62

80

100

115

142

  • Base-load current IL1)

A

52

62

80

100

115

142

  • Base-load current IH2)

A

42

52

62

80

100

115

  • Maximum current Imax

A

71

84

108

135

156

192

Rated power

 

 

 

 

 

 

 

  • Based on IL

kW

45

55

75

90

110

132

  • Based on IH

kW

37

45

55

75

90

110

Rated pulse frequency

kHz

2

2

2

2

2

2

Efficiency η

%

99

99

99

99

99

99

Power loss 3)

at rated current

 

 

 

 

 

 

 

  • Without integrated line filter

kW

1.08

1.3

1.37

1.75

1.95

2.49

  • With integrated line filter

kW

1.09

1.31

1.38

1.76

1.97

2.51

Cooling air requirement

m3/s (ft3/s)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

0.055 (1.94)

Sound pressure level

LpA (1 m)

dB

70.6

70.6

67.7

67.7

67.7

67.7

24 V DC power supply

for Control Unit

A

1

1

1

1

1

1

Rated input current Irated4)

A

50

59

78

97

111

137

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminal

Screw-type terminal

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

25 ... 70

25 ... 70

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Motor connection

U2, V2, W2

 

Screw-type terminal

Screw-type terminal

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

25 ... 70

25 ... 70

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Feedback connection

F3, R1

 

Screw-type terminal

Screw-type terminal

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

25 ... 70

25 ... 70

35 ... 2 x 120

35 ... 2 x 120

35 ... 2 x 120

35 ... 2 x 120

PE connection

 

Screw-type terminal

Screw-type terminal

M10 screw stud

M10 screw stud

M10 screw stud

M10 screw stud

  • Conductor cross-section

mm2

25 ... 70

25 ... 70

35 ... 120

35 ... 120

35 ... 120

35 ... 120

Motor cable length 5), max.

 

 

 

 

 

 

 

  • Shielded

m (ft)

200 (656)

200 (656)

300 (984)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

300 (984)

300 (984)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

275 (10.8)

275 (10.8)

305 (12.01)

305 (12.01)

305 (12.01)

305 (12.01)

  • Height

mm (in)

551 (21.7)

551 (21.7)

708 (27.9)

708 (27.9)

708 (27.9)

708 (27.9)

  • Depth

 

 

 

 

 

 

 

  • Without operator panel

mm (in)

237 (9.33)

237 (9.33)

357 (14.1)

357 (14.1)

357 (14.1)

357 (14.1)

  • With Control Unit and operator panel, max.

mm (in)

274.5 (10.8)

274.5 (10.8)

394.5 (15.5)

394.5 (15.5)

394.5 (15.5)

394.5 (15.5)

Frame size

 

FSE

FSE

FSF

FSF

FSF

FSF

Weight, approx.

 

 

 

 

 

 

 

  • Without integrated line filter

kg (lb)

26 (57.3)

26 (57.3)

60 (132)

60 (132)

60 (132)

60 (132)

  • With integrated line filter

kg (lb)

28 (61.7)

28 (61.7)

64 (141)

64 (141)

64 (141)

64 (141)

 

1) The rated output current Irated and the base-load current IL are based on the duty cycle for low overload (LO).

2) The base-load current IH is based on the duty cycle for high overload (HO).

3) Maximum values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uK = 1 %.

5) The specified cable lengths apply to Power Modules without output option and without compliance with the limit values for RI suppression.
 

Characteristic curves

Derating data

Current derating as a function of the pulse frequency

Rated power

Rated output current in A

for a pulse frequency of

400 V

460 V

kW

hp

2 kHz

4 kHz

6 kHz

8 kHz

10 kHz

12 kHz

14 kHz

16 kHz

22

25

45

45

38.3

31.5

27

22.5

20.3

18

30

30

60

60

51

42

36

30

27

24

37

40

75

75

63.8

52.5

45

37.5

33.8

30

45

50

90

90

76.5

63

54

45

40.5

36

55

60

110

110

93.5

77

66

55

49.5

44

75

75

145 1)

145

123.3

101.5

90

100

178 1)

178

151.3

124.6

110

125

205 1)

143.5

132

150

250 1)

175

 

1) For these Power Modules, the factory default pulse frequency setting is 2 kHz. If switched over to 4 kHz, the RFI suppression limit values for Category C3 are complied with.

Rated power

Rated output current in A

for a pulse frequency of

690 V

575 V

kW

hp

2 kHz

4 kHz

11

10

14

8.4

15

15

19

11.4

18.5

20

23

13.8

22

25

27

16.2

30

30

35

21

37

40

42

25.2

45

50

52

31.2

55

60

62

37.2

75

75

80

48

90

100

100

60

110

100

115

69

132

125

142

85.2

 

Current derating as a function of ambient temperature

Permissible output current as a function of the ambient temperature for low overload (LO) and high overload (HO)

Note:

The operating temperature ranges of the Control Units should be taken into account. The temperature ranges are specified in the section Technical specifications under Control Units.

Current derating as a function of the installation altitude

Permissible line supplies as a function of the installation altitude

  • Installation altitude up to 2000 m (6562 ft) above sea level
    • Connection to every supply system permitted for the inverter
  • Installation altitudes between 2000 m (6562 ft) and 4000 m (13124 ft) above sea level
    • Connection to a TN system with grounded neutral point
    • TN systems with grounded line conductor are not permitted
    • The TN line system with grounded neutral point can also be supplied using an isolation transformer
    • The phase-to-phase voltage does not have to be reduced

Permissible output current as a function of the installation altitude

Note:

The connected motors, power elements and components must be considered separately.

Current derating as a function of the installation altitude and the ambient temperature

At installation altitudes above 1000 m (3281 ft), the permissible output current can be compensated to a certain extent using the ambient temperature.

Installation altitude above sea level

Current derating factor (in % of the base-load output current IL) at an ambient temperature of

m (ft)

0 °C (32 °F)

5 °C (41 °F)

10 °C (50 °F)

15 °C (59 °F)

20 °C (68 °F)

25 °C (122 °F)

30 °C (86 °F)

35 °C (95 °F)

40 °C (104 °F)

45 °C (113 °F)

50 °C (122 °F)

55 °C (131 °F)

60 °C (140 °F)

0 ... 1000 (0 ... 3281)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

93 %

85 %

76 %

66 %

1000 ... 1500 (3281 ... 4921)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

95 %

88 %

81 %

72 %

63 %

1500 ... 2000 (4921 ... 6562)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

97 %

90 %

83 %

77 %

68 %

59 %

2000 ... 2500 (6562 ... 8202)

100 %

100 %

100 %

100 %

100 %

100 %

98 %

91 %

85 %

79 %

72 %

64 %

56 %

2500 ... 3000 (8202 ... 9843)

100 %

100 %

100 %

100 %

100 %

98 %

92 %

86 %

80 %

74 %

68 %

60 %

53 %

3000 ... 3500 (9843 ... 11483)

98 %

98 %

98 %

98 %

98 %

92 %

86 %

81 %

75 %

69 %

64 %

57 %

50 %

3500 ... 4000 (11483 ... 13123)

91 %

91 %

91 %

91 %

91 %

86 %

81 %

75 %

70 %

65 %

60 %

53 %

46 %

 

 

Installation altitude above sea level

Current derating factor (in % of the base-load output current IH) at an ambient temperature of

m (ft)

0 °C (32.0 °F)

5 °C (41.0 °F)

10 °C (50.0 °F)

15 °C (59.0 °F)

20 °C (68.0 °F)

25 °C (77.0 °F)

30 °C (86.0°F)

35 °C (95.0 °F)

40 °C (104 °F)

45 °C (113 °F)

50 °C (122 °F)

55 °C (131 °F)

60 °C (140 °F)

0 ... 1000 (0 ... 3281)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

87 %

74 %

1000 ... 1500 (3281 ... 4921)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

95 %

83 %

70 %

1500 ... 2000 (4921 ... 6562)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

100 %

99 %

95 %

90 %

78 %

67 %

2000 ... 2500 (6562 ... 8202)

100 %

100 %

100 %

100 %

100 %

100 %

100 %

98 %

94 %

89 %

85 %

74 %

63 %

2500 ... 3000 (8202 ... 9843)

100 %

100 %

100 %

100 %

100 %

100 %

96 %

92 %

88 %

84 %

80 %

70%

59 %

3000 ... 3500 (9843 ... 11483)

98 %

98 %

98 %

98 %

98 %

94 %

90 %

86 %

83 %

79 %

75 %

65 %

56 %

3500 ... 4000 (11483 ... 13123)

91 %

91 %

91 %

91 %

91 %

88 %

84 %

81 %

77 %

74 %

70 %

61 %

52 %

 

Current/power derating as a function of the line voltage

PM240P-2 Power Modules supply a constant power in the line voltage range 380 V to 480 V 3 AC. The constant power results in current derating as a function of the line voltage.

 

PM240P-2 Power Modules supply a constant output current in the line voltage range 500 V to 690 V 3 AC. Output power derating takes place as a function of the line voltage.

Overload capability

The Power Modules are equipped with an overload reserve e.g. to handle breakaway torques. If larger surge loads occur, this must be taken into account in the configuration. For drives with overload requirements, the appropriate base-load current must, therefore, be used as a basis for the required load.

The units can operate in two different duty cycles in the permissible continuous operating range. Depending on how the system is dimensioned, the relevant base-load current is effective as a rated quantity.

The criterion for overload is that the inverter is operated with its base-load current before and after the overload occurs on the basis of a duty cycle duration of 300 s.

The base-load current IL for low overload is the basis for a duty cycle of 135 % for 3 s plus 110 % for 57 s.

The base-load current IH for a high overload is based on a duty cycle of 150 % for 60 s.

Overload capability, low overload

Overload capability, high overload

 

Dimensional drawings

PM240P-2 Power Modules


Principle dimension drawing and drill pattern for PM240P-2 Power Module

 

Frame size

Dimensions

in mm (inches)

Drilling dimensions

in mm (inches)

Cooling clearance

in mm (inches)

Mounting

 

a
(width)

b
(height)

c
(depth) 1)

d

e

f

top

bottom

front

With bolts

PM240P-2 Power Modules

FSD

200
(7.87)

472
(18.58)

237
(9.33)

170
(6.69)

430
(16.93)

15
(0.59)

300
(11.81)

350
(13.78)

100
(3.94)

4 × M5

FSE

275
(10.83)

551
(21.69)

237
(9.33)

230
(9.06)

509
(20.04)

11
(0.43)

300
(11.81)

350
(13.78)

100
(3.94)

4 x M6

FSF

305
(12.01)

708
(27.87)

357
(14.06)

270
(10.63)

680
(26.77)

13
(0.51)

300
(11.81)

350
(13.78)

100
(3.94)

4 × M8

 

1) Increase in Power Module mounting depth:

• When the CU230P‑2 Control Unit is plugged on, the depth increases by 15.5 mm (0.61 in)

• When the IOP is plugged on, the depth increases by a further 22 mm (0.87 in)

• When the BOP‑2 is plugged on, the depth increases by a further 11 mm (0.43 in)

  

(Nguyễn Thảo Trường - http://DienElectric.com theo Siemens)